Wylex 12W FLEXIBLE SPLIT LOAD FUSEBOARD - 17TH EDITION AMENDMENT 3

REF: NMRS12SLM

£66.69 ex. VAT
( £80.03 inc. VAT )

Wylex 12W FLEXIBLE SPLIT LOAD FUSEBOARD - 17TH EDITION AMENDMENT 3

Quantity


Order before 2pm for next working day delivery*

The Wylex NMRS12SLM is a 17th Edition – Amendment 3 Flexible Split Load non combustible metal fuseboard, suitable for installation in domestic household premises.

The flexible split load board holds:

RCD Rating – 80A 30mA

MCB Ways Min / Max – 3 / 9

MS Rating – 100A

Total Ways - 12

Main features of the NMRS12SLM are:

All metal enclosure – No external plastic parts

Low smoke and fume paint

Non combustible cover blanks

5 entry points for cable – Knockouts at the top, bottom, left, right and rear

Mains tail cable entry grommet / gland

Removable & raised DIN rail / busbar assembly

Main changes to the 17th Edition, Amendment 3 are:

Consumer units (Effective January 2016)

Wiring in escape routes

Changes to earth fault loop impedances for all protective devices

Updated EIC and EICR forms

Changes to definitions throughout the Regulations

From 1st July 2015 all new installations must comply with amendment 3 to BS 7671:2008.

RoHS compliant in excess of the UK standards

UKAS certified to BS EN 61439-3


17TH EDITION AMENDMENT 3 FUSEBOARD

The Wylex NMRS12SLM is a 17th Edition – Amendment 3 Flexible Split Load non combustible metal fuseboard, suitable for installation in domestic household premises.

The flexible split load board holds:

RCD Rating – 80A 30mA

MCB Ways Min / Max – 3 / 9

MS Rating – 100A

Total Ways - 12

Main features of the NMRS12SLM are:

All metal enclosure – No external plastic parts

Low smoke and fume paint

Non combustible cover blanks

5 entry points for cable – Knockouts at the top, bottom, left, right and rear

Mains tail cable entry grommet / gland

Removable & raised DIN rail / busbar assembly

Main changes to the 17th Edition, Amendment 3 are:

Consumer units (Effective January 2016)

Wiring in escape routes

Changes to earth fault loop impedances for all protective devices

Updated EIC and EICR forms

Changes to definitions throughout the Regulations

From 1st July 2015 all new installations must comply with amendment 3 to BS 7671:2008.

RoHS compliant in excess of the UK standards

UKAS certified to BS EN 61439-3