Order and Helpline Open Now
800 652 9229
Shoping Basket
Menu

Hawke 501/453/UNIV/B/KIT E1FW CABLE GLAND - 25

REF: 501/453/UNIVBT

£20.95 ex. VAT
( £25.14 inc. VAT )

Hawke  501/453/UNIV/B/KIT E1FW CABLE GLAND - 25

Quantity:



Deliveries:
Order before 2:30pm for next working day delivery* [more]

Click & Collect:
Order now to collect from our Middlesbrough Depot on Monday between 9am and 5pm. [more]

Hawke 501/453/UNIV Group II Cable Glands suitable for outdoor or indoor for use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’, elastomer and plastic insulated cables.

501/453/UNIV Glands are for particular use with cables that exhibit ‘Cold Flow’ characteristics.

Overview of the gland:

Flameproof, Increased safety, Dust Protection & Restricted Breathing

Class / Zones / Divisions

Certified ATEX / IECEx / c CSA us

Provides armour clamping using one clamping arrangement for all armour / braid types.

Provides a diaphragm seal on inner sheath of cable which will not damage cables that exhibit ‘Cold Flow’ characteristics.

Provides an outer deluge seal to prevent moisture ingress to the cable armour / braid.

Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer sheath.

Manufactured in brass

B gland specification:

Entry thread metric – M25

Entry thread NPT – 1” or ¾”

Inner sheath – Min 11.1 / Max 19.7mm

Outer sheath – Min 16.9 / Max 26.0mm

Armour / Braid – Orientation 1 1.25 / 1.6 – Orientation 2 0.0 / 0.7


E1FW HAWKE CABLE GLAND - 25

Hawke 501/453/UNIV Group II Cable Glands suitable for outdoor or indoor for use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’, elastomer and plastic insulated cables.

501/453/UNIV Glands are for particular use with cables that exhibit ‘Cold Flow’ characteristics.

Overview of the gland:

Flameproof, Increased safety, Dust Protection & Restricted Breathing

Class / Zones / Divisions

Certified ATEX / IECEx / c CSA us

Provides armour clamping using one clamping arrangement for all armour / braid types.

Provides a diaphragm seal on inner sheath of cable which will not damage cables that exhibit ‘Cold Flow’ characteristics.

Provides an outer deluge seal to prevent moisture ingress to the cable armour / braid.

Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer sheath.

Manufactured in brass

B gland specification:

Entry thread metric – M25

Entry thread NPT – 1” or ¾”

Inner sheath – Min 11.1 / Max 19.7mm

Outer sheath – Min 16.9 / Max 26.0mm

Armour / Braid – Orientation 1 1.25 / 1.6 – Orientation 2 0.0 / 0.7

Ask a question

Need to double check something about this product? Ask us a question



Customer Reviews




* SUBJECT TO STOCK AVAILABILITY