Alarm Systems Electrical Cables
Steel Wire Armoured Cables - BS5467 - PVC Steel Wire Armoured Cables - BS6724 - LSZH 6941AX/AB Single Core AWA Cables - PVC & LSZH 6491X H07V-R Cables - BS EN 50525-2-3 - PVC 6491B HO7Z-R Cables - BS EN 50525-3-41 - LSZH NYY-J Cables - IEC60502-1 - PVC N2XH Cables - BS EN / IEC 60332-3-24 (c) - LSZH ConnectEV Electric Vehicle Power & CAT5e Cable EV-Ultra Electric Vehicle Power & CAT5e Cable Bare Soft Drawn Copper Cables Bare Hard Drawn Copper Cables 6181Y Double Insulated ( Meter Tails ) Cables - BS6004 - PVC 6242 / 6243 Twin & Earth Cables - BS6004 - PVC 6181B Double Insulated ( Meter Tails ) Cables - BS7211 & BS8573 / IEC60502 - LSZH 6242 / 6243 Twin & Earth Cables - BS7211- LSZH 218*Y H03VV-F Flexible Cord 219*Y PVC Oval Flat Flexible Cables - BS6500 318*Y Flex Cables - H05VV-F - PVC 3093 / 3094 & 3095 PVC Heat Resistant Flexible Cables - BS EN 50265 318*B Flex Cables - HO5Z1Z1-F - LSZH Arctic Grade Flexible Cables - BS6004 - Table 44 Solar Cables - TUV Approved PV-Ultra Solar Cable Fire Alarm & Security Cables - BS5839/BS7629 Fire Alarm & Security Cables - Enhanced - BS5839 / BS7629 6491F Single Core Fireproof Cables Fireproof Mains & Control Cables - LSZH Fireproof Mains Cables - LSZH Fireproof Mains & Control Cables - Enhanced - LSZH Fireproof Mains Cables - Enhanced - LSZH 318* Tough Rubber Flex Cords H07RN-F Flex Mains & Control Cables - EPR H07ZZ-F Flex Mains & Control Cables - LSZH TQ Flexible Cables - EPR / CSP Type 4 Coil End Lead Cable 0361TQ Welding Cable - BS638 Part 4 YY Control Cables - BS50525-2-11 - PVC YY Control Cables - BS50525-2-11 - LSZH SY Control Cables - BS50525-2-11 - PVC SY Control Cables - BS50525-2-11 - LSZH CY Control Cables - BS50525-2-11 - PVC CY Control Cables - BS50525-2-11 - LSZH BS8436 Protected Fixed Wiring Cable Tri Rated Cables - BS6231 2491B / 6701B Cables - LSZH NYMJ Cables NHXMHJ Cables Security Alarm Cables Belden Equivalent Cables UTP/FTP CAT5E/CAT6 Data Cables Internal Telephone Cables - BS4066 Coaxial Cables Bell Wire & Speaker Cables Defence Standard 61-12 Control Cables KNX Cables ENATS 09-6 Communications & Telephone Cables BS5308 Instrumentation Cables 6381Y DC Cables - PVC 6381B DC Cables - LSZH 6181X Mains & Cathodic Cables - BS7889/97 - PVC 6941X Armoured Cathodic Protection Cables - PVC Induction Loop Detector Cable - BS6500 / BS6195 Steel Wire Armoured Cables - Aluminium - BS5467 - PVC DNO Concentric Cables - Split & Straight DNO Waveform Cable DNO 11KV Cable 11kV Armoured Mains Cable - Single Core - LSZH 11kV Armoured Mains Cable - 3 Core - PVC 11kV Armoured Mains Cable - 3 Core - LSZH 657*TQ Marine & Offshore Cables 658*TQ Marine & Offshore Cables XAI Marine Instrumentation Cables XAI Marine Power Cables
Cable Accessories & Components Cable Management Lamps & Lighting LED Heating & Hand Dryers Site Equipment Switchgear & Control Switches & Sockets Ventilation Fans & Ducting Wiring Accessories & Consumables
01642 266013
0800 652 9229
Order and Helpline open now
Prices Ex. VAT Prices Inc. VAT
Free Delivery On orders over £50 to UK mainland
postcodes. Click to see exceptions.
Place Your Order before 2.30pm for same day dispatch Mon-Fri
Open 8.30am-5pm Mon-Fri, 8am-12pm Sat
Click & Collect Available from our Middlesbrough depot Cable Size Calculator Step by step size selector
 
Images for illustration purposes only

11kV BS7835 Power Cable 3 Core 150mm² XLPE CTS SWA Red LSZH

10312RD
£64.05EX. VAT
£76.86INC. VAT
In Stock
Order before 2.30pm for same day dispatch*
Order now to collect from our Middlesbrough Depot in 2 hours time*
Length (m):
Quantity:
Add To Basket

Overview

The 11KV Medium Voltage British Standard cable is suitable for installation in power networks, underground and in cable ducting. Its low smoke zero halogen sheath makes it suitable for installations where fire, smoke emissions and toxic fumes create a potential threat.

Please note: Due to poor UV resistant qualities, red outer sheath cables are not recommended for outdoor installation.

Standards

  • BS7835
  • BS EN50268 (IEC 61034)
  • Flame propagation to BS EN 50265
  • BS EN 50266 (IEC 60332)

Construction

  • Conductor: Stranded Plain Annealed Circular Compacted Copper Conductors
  • Insulation: Cross Link Polyethylene (XLPE)
  • Metallic Screen: Individual or overlapped copper tape screen
  • Bedding: Low Smoke Zero Halogen (LSZH)
  • Separator: Copper Binding Tape 10% Overlap
  • Armouring: Galvanised Steel Wire Armour
  • Sheath: Low Smoke Zero Halogen (LSZH)
  • Sheath Colour: Red

Characteristics

  • Voltage Rating: 6350/11000 Volts (12KV)
    Tested to Voltage and Duration of BS7835
  • Temperature Rating: -15°C to +90°C
  • Minimum Bending Radius: As per cable manufacturer datasheet

Should not be installed at temperatures below 0°C or above +60°C

Please note: If you require advice on which cable to use or how and where to install it, it is recommended that you consult a relevant qualified tradesperson. The Superlec Direct team are not qualified electricians.

Project Pricing Available
Superlec Code 10312RD
Colour Red
Conductor 150mm²
Cores 3
Stranding 37/2.25
Weight 9292kg/km
Diameter 69.8mm
Nylon Cleat TC11
11kV Armoured Mains Cable Datasheet