Alarm Systems Electrical Cables
Steel Wire Armoured Cables - BS5467 - PVC Steel Wire Armoured Cables - BS6724 - LSZH 6941AX/AB Single Core AWA Cables - PVC & LSZH 6491X H07V-R Cables - BS EN 50525-2-3 - PVC 6491B HO7Z-R Cables - BS EN 50525-3-41 - LSZH NYY-J Cables - IEC60502-1 - PVC N2XH Cables - BS EN / IEC 60332-3-24 (c) - LSZH ConnectEV Electric Vehicle Power & CAT5e Cable EV-Ultra Electric Vehicle Power & CAT5e Cable Bare Soft Drawn Copper Cables Bare Hard Drawn Copper Cables 6181Y Double Insulated ( Meter Tails ) Cables - BS6004 - PVC 6242 / 6243 Twin & Earth Cables - BS6004 - PVC 6181B Double Insulated ( Meter Tails ) Cables - BS7211 & BS8573 / IEC60502 - LSZH 6242 / 6243 Twin & Earth Cables - BS7211- LSZH 218*Y H03VV-F Flexible Cord 219*Y PVC Oval Flat Flexible Cables - BS6500 318*Y Flex Cables - H05VV-F - PVC 3093 / 3094 & 3095 PVC Heat Resistant Flexible Cables - BS EN 50265 318*B Flex Cables - HO5Z1Z1-F - LSZH Arctic Grade Flexible Cables - BS6004 - Table 44 Solar Cables - TUV Approved PV-Ultra Solar Cable Fire Alarm & Security Cables - BS5839/BS7629 Fire Alarm & Security Cables - Enhanced - BS5839 / BS7629 6491F Single Core Fireproof Cables Fireproof Mains & Control Cables - LSZH Fireproof Mains Cables - LSZH Fireproof Mains & Control Cables - Enhanced - LSZH Fireproof Mains Cables - Enhanced - LSZH 318* Tough Rubber Flex Cords H07RN-F Flex Mains & Control Cables - EPR H07ZZ-F Flex Mains & Control Cables - LSZH TQ Flexible Cables - EPR / CSP Type 4 Coil End Lead Cable 0361TQ Welding Cable - BS638 Part 4 YY Control Cables - BS50525-2-11 - PVC YY Control Cables - BS50525-2-11 - LSZH SY Control Cables - BS50525-2-11 - PVC SY Control Cables - BS50525-2-11 - LSZH CY Control Cables - BS50525-2-11 - PVC CY Control Cables - BS50525-2-11 - LSZH BS8436 Protected Fixed Wiring Cable Tri Rated Cables - BS6231 2491B / 6701B Cables - LSZH NYMJ Cables NHXMHJ Cables Security Alarm Cables Belden Equivalent Cables UTP/FTP CAT5E/CAT6 Data Cables Internal Telephone Cables - BS4066 Coaxial Cables Bell Wire & Speaker Cables Defence Standard 61-12 Control Cables KNX Cables ENATS 09-6 Communications & Telephone Cables BS5308 Instrumentation Cables 6381Y DC Cables - PVC 6381B DC Cables - LSZH 6181X Mains & Cathodic Cables - BS7889/97 - PVC 6941X Armoured Cathodic Protection Cables - PVC Induction Loop Detector Cable - BS6500 / BS6195 Steel Wire Armoured Cables - Aluminium - BS5467 - PVC DNO Concentric Cables - Split & Straight DNO Waveform Cable DNO 11KV Cable 11kV Armoured Mains Cable - Single Core - LSZH 11kV Armoured Mains Cable - 3 Core - PVC 11kV Armoured Mains Cable - 3 Core - LSZH 657*TQ Marine & Offshore Cables 658*TQ Marine & Offshore Cables XAI Marine Instrumentation Cables XAI Marine Power Cables
Cable Accessories & Components Cable Management Lamps & Lighting LED Heating & Hand Dryers Site Equipment Switchgear & Control Switches & Sockets Ventilation Fans & Ducting Wiring Accessories & Consumables
01642 266013
0800 652 9229
Order and Helpline open now
Prices Ex. VAT Prices Inc. VAT
Free Delivery On orders over £50 to UK mainland
postcodes. Click to see exceptions.
Place Your Order before 2.30pm for same day dispatch Mon-Fri
Open 8.30am-5pm Mon-Fri, 8am-12pm Sat
Click & Collect Available from our Middlesbrough depot Cable Size Calculator Step by step size selector
 

Cavius CV4002 Carbon Monoxide Alarm 40mm

CV4002
£25.65EX. VAT
£30.78INC. VAT
Awaiting Del.
Order before 2.30pm for same day dispatch*
Order now to collect from our Middlesbrough Depot in 2 hours time*
Quantity:

*** THIS PRODUCT IS NOW OBSOLITE ***

 

BSEN 20921

DEVICE TYPE: Carbon monoxide alarm device.

BATTERY TYPE: Non-replaceable 10 year battery 

NORMAL OPERATION: LED flashes every 60 seconds for normal operation.

FUNCTION: The alarm will make a CO sensor reading every 30 seconds if the concentration is less than 200ppm. At 200ppm or higher, the readings will be made every 10 seconds. 

SOUND: Audible indicator min. 85 dB @ 3 meters in an anechoic chamber.

OPERATION AC/DC: DC

LOW BATTERY INDICATION: A short acoustic “beep” will sound and LED flash every 48 seconds when the voltage is below 2.85V. In this stage, it will continue for a minimum of 30 days and can drive the alarm for 4 minutes.

USAGE: Designed for installation in private homes, camping trailers, mobile homes, and caravans. 

POWER CONSUMPTION: Battery consumption is 82mAh for 1 year in the nonalarm condition.

PUSH BUTTON: The CO sensor includes a push-button switch at the top of the alarm, for easy access.
• hush – during an alarm condition (under a level of 220ppm) this immediately silences the alarm for about 
10 minutes when pressed. When battery fault the indication can also be silenced for up to 8 hours by a short press on the hush/test button. 

This function can only be carried out once during a fault
• test – when not in alarm the sounder can be activated to provide a sensor OK test function. When the top button is released, the audible and visible indicators are activated to show if the sensor is OK. The alarm will also do a self-test every 24 hour

DETECTION TIMING: Cavius CO-alarm alerts you according to the following levels (PPM=parts per million): 
• 0-50 ppm (green): Safe 
• 50-100ppm (yellow): Alarm starts after 60-90 minutes
• 100-300ppm (orange): Alarm starts after 10-40 minutes
• 300+ppm (red): Alarm starts in 3 minutes or less

WARRANTY: 10 year

BATTERY LIFE: Minimum 10-year life in normal operating condition.

INSTALLATION POSITION: Wall & ceiling. Set of 2 x screws and 2 x plugs included.

PRODUCT DIMENSIONS: D: 40 mm. x H: 38 mm. 

PRODUCT WEIGHT: Base alarm weight (excluding screws, plugs, and mounting ring): 40 g.

Quantity Price Inc. VAT Price Ex. VAT
1 - 9 £30.78 £25.65
10 - 999 £29.94 £24.95
cavius cv4002 Installation Guide cavius cv4002 user guide cavius cv4002 datasheet