Order and Helpline Open Now
0800 652 9229
Shoping Basket
Menu

Superlec 4X35 MICA,XL,LZH,SWA,LZH ENHANCED 1KV BS7346-6,BS8491,BS8519

REF: FPE4X35

£31.19 ex. VAT
( £37.43 inc. VAT )

Superlec 4X35 MICA,XL,LZH,SWA,LZH ENHANCED 1KV BS7346-6,BS8491,BS8519

Quantity:



Deliveries:
Order before 2:30pm for next working day delivery* [more]

Click & Collect:
Order now to collect from our Middlesbrough Depot on Saturday between 9am and 12pm. [more]

Fireproof mains cable, suitable for fixed installations such as power circuits, fire alarm systems and emergency lighting. Specifically designed to meet the stringent standards of BS8491, which includes enhanced resistance to heat and fire, direct impact of 10N and water jet as would be produced by a fire fighting unit.

CABLE STANDARDS

BS7846/ BS8491

Circuit integrity: BS8519-2010 120 minutes / BS8491, acid gas emission to IEC 60754

Flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3). Smoke emission to IEC 60332-3

BS EN 50267, BS EN 50268

BASEC Approved

LPCB Approved

CONSTRUCTION

Conductor: Plain Annealed Stranded Copper Conductor

Separator: MICA/Glass Fire Barrier Tape

Insulation: Cross Link Polyethylene (XLPE)

Bedding: Low Smoke Zero Halogen (LSZH)

Armouring: Galvanised Steel Wire Armour

Sheath: Low Smoke Zero Halogen (LSZH)

Sheath Colour: Black

CHARACTERISTICS

Voltage Rating: 600/1000 volts

Temperature limits: -10°C to +90°C

Minimum Bending Radius: As Per Manufacturers Datasheet


4X35 MICA,XL,LZH,SWA,LZH ENHANCED 1KV BS7346-6,BS8491,BS8519

Fireproof mains cable, suitable for fixed installations such as power circuits, fire alarm systems and emergency lighting. Specifically designed to meet the stringent standards of BS8491, which includes enhanced resistance to heat and fire, direct impact of 10N and water jet as would be produced by a fire fighting unit.

CABLE STANDARDS

BS7846/ BS8491

Circuit integrity: BS8519-2010 120 minutes / BS8491, acid gas emission to IEC 60754

Flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3). Smoke emission to IEC 60332-3

BS EN 50267, BS EN 50268

BASEC Approved

LPCB Approved

CONSTRUCTION

Conductor: Plain Annealed Stranded Copper Conductor

Separator: MICA/Glass Fire Barrier Tape

Insulation: Cross Link Polyethylene (XLPE)

Bedding: Low Smoke Zero Halogen (LSZH)

Armouring: Galvanised Steel Wire Armour

Sheath: Low Smoke Zero Halogen (LSZH)

Sheath Colour: Black

CHARACTERISTICS

Voltage Rating: 600/1000 volts

Temperature limits: -10°C to +90°C

Minimum Bending Radius: As Per Manufacturers Datasheet

Ask a question

Need to double check something about this product? Ask us a question



Customer Reviews




* SUBJECT TO STOCK AVAILABILITY