Superlec 10CORE 2.5MM LSZH BS6724 STEEL WIRE ARMOURED CABLE NUMBERED CORES
REF: LSF10X2/5
£4.84 ex. VAT
( £5.81 inc. VAT )

* PLEASE NOTE THAT THE AMOUNT YOU SELECT AS THE QUANTITY WILL BE IN ONE CONTINUOUS LENGTH *
Please note: If you require advice on which cable to use, how and where to install it, it is recommended that you will need to contact the relevant qualified tradesperson for the job as the Superlec Direct Team are not qualified electricians.
OVERVIEW
Used in power networks, indoor, outdoor, underground and in cable ducting. For installation where fire, smoke emissions and toxic fumes create a potential threat to life and equipment.
STANDARDS
- BS6724
- Acid gas emission to BS EN 50267 (IEC 60754-1)
- Smoke emission to BS EN 50268 (IEC 61034)
- Flame propagation: IEC 60332-1, IEC60332-3, BS EN 50265, Category C; BS EN 50266
- BASEC Approved
CONSTRUCTION
- Conductor: Plain Annealed Stranded Copper Conductors
- Insulation: Cross Linked Polyethylene (XLPE)
- Bedding: Low Smoke Zero Halogen (LSZH)
- Armouring: Galvanised Steel Wire Armour
- Sheath: Low Smoke Zero Halogen (LSZH)
- Sheath Colour: Black
CHARACTERISTICS
- Voltage Rating: 600/1000 Volts
- Temperature limits: -25°C to +90°C
- Minimum Bending Radius: As Per Manufacturers Datasheet
Should not be installed at temperatures below 0°C or above +40°C
CORE IDS
- 2 core: Brown, Blue
- 3 core: Brown, Black, Grey
- 3 core (up to 35mm2): Brown, Blue, Green/Yellow
- 4 core: Brown, Black, Grey, Blue
- 5 core and above (up to 6mm2): White with Black numbers
- 2, 3, 4 or 5 core (1.5mm2 & 2.5mm2): White
- Also available as: Brown, Black, Grey, Blue, Green/Yellow
600 / 1000 VOLTS TO BS6724 - XLPE / LSZH BEDDING / SWA / LSZH OUTER CABLE
* PLEASE NOTE THAT THE AMOUNT YOU SELECT AS THE QUANTITY WILL BE IN ONE CONTINUOUS LENGTH *
* PLEASE NOTE THAT THE AMOUNT YOU SELECT AS THE QUANTITY WILL BE IN ONE CONTINUOUS LENGTH *
Please note: If you require advice on which cable to use, how and where to install it, it is recommended that you will need to contact the relevant qualified tradesperson for the job as the Superlec Direct Team are not qualified electricians.
OVERVIEW
Used in power networks, indoor, outdoor, underground and in cable ducting. For installation where fire, smoke emissions and toxic fumes create a potential threat to life and equipment.
STANDARDS
- BS6724
- Acid gas emission to BS EN 50267 (IEC 60754-1)
- Smoke emission to BS EN 50268 (IEC 61034)
- Flame propagation: IEC 60332-1, IEC60332-3, BS EN 50265, Category C; BS EN 50266
- BASEC Approved
CONSTRUCTION
- Conductor: Plain Annealed Stranded Copper Conductors
- Insulation: Cross Linked Polyethylene (XLPE)
- Bedding: Low Smoke Zero Halogen (LSZH)
- Armouring: Galvanised Steel Wire Armour
- Sheath: Low Smoke Zero Halogen (LSZH)
- Sheath Colour: Black
CHARACTERISTICS
- Voltage Rating: 600/1000 Volts
- Temperature limits: -25°C to +90°C
- Minimum Bending Radius: As Per Manufacturers Datasheet
Should not be installed at temperatures below 0°C or above +40°C
CORE IDS
- 2 core: Brown, Blue
- 3 core: Brown, Black, Grey
- 3 core (up to 35mm2): Brown, Blue, Green/Yellow
- 4 core: Brown, Black, Grey, Blue
- 5 core and above (up to 6mm2): White with Black numbers
- 2, 3, 4 or 5 core (1.5mm2 & 2.5mm2): White
- Also available as: Brown, Black, Grey, Blue, Green/Yellow