Superlec 3CORE 1.5MM NYY-J NON ARMOURED MAINS CABLE IEC60502-1
REF: NYY3X1/5
£0.55 ex. VAT
( £0.66 inc. VAT )

Please note: If you require advice on which cable to use, how and where to install it, it is recommended that you will need to contact the relevant qualified tradesperson for the job as the Superlec Direct Team are not qualified electricians.
** Please note that the amount you select as the quantity will be in one continuous length **
OVERVIEW
Unarmoured power and control cable is most suited for energy supply in fixed installations. NYY Cable can be installed indoors where there is little chance of mechanical damage. Cables can be fixed on cable trays, within conduits or fixed to walls. This cable is not suitable for direct burial.
STANDARDS
- BS EN / IEC 60332-1-2
- IEC 60502-1
CONSTRUCTION
- Conductor:
- Up to 6mm2: Class 1 solid copper conductor
- Above 10mm2: Class 2 stranded copper
- Insulation: PVC (Poly Vinyl Chloride)
- Filler: PVC (Poly Vinyl Chloride)
- Sheath: PVC (Poly Vinyl Chloride)
CHARACTERISTICS
- Voltage Rating: 600/1000 Volts
- Temperature Limits: -30°C to +70°C
- Minimum Bending Radius: As per cable manufacturer datasheet
Should not be installed at temperatures below 0°C
CORE IDS
- 2 core: Brown, Blue
- 3 core: Brown, Blue, Green/Yellow
- 4 core: Brown, Blue, Black, Green/Yellow
- 5 core: Brown, Blue, Black, Grey, Green/Yellow
NON ARMOURED NYY-J MAINS & CONTROL CABLE
Please note: If you require advice on which cable to use, how and where to install it, it is recommended that you will need to contact the relevant qualified tradesperson for the job as the Superlec Direct Team are not qualified electricians.
** Please note that the amount you select as the quantity will be in one continuous length **
OVERVIEW
Unarmoured power and control cable is most suited for energy supply in fixed installations. NYY Cable can be installed indoors where there is little chance of mechanical damage. Cables can be fixed on cable trays, within conduits or fixed to walls. This cable is not suitable for direct burial.
STANDARDS
- BS EN / IEC 60332-1-2
- IEC 60502-1
CONSTRUCTION
- Conductor:
- Up to 6mm2: Class 1 solid copper conductor
- Above 10mm2: Class 2 stranded copper
- Insulation: PVC (Poly Vinyl Chloride)
- Filler: PVC (Poly Vinyl Chloride)
- Sheath: PVC (Poly Vinyl Chloride)
CHARACTERISTICS
- Voltage Rating: 600/1000 Volts
- Temperature Limits: -30°C to +70°C
- Minimum Bending Radius: As per cable manufacturer datasheet
Should not be installed at temperatures below 0°C
CORE IDS
- 2 core: Brown, Blue
- 3 core: Brown, Blue, Green/Yellow
- 4 core: Brown, Blue, Black, Green/Yellow
- 5 core: Brown, Blue, Black, Grey, Green/Yellow