Alarm Systems Electrical Cables
Steel Wire Armoured Cables - BS5467 - PVC Steel Wire Armoured Cables - BS6724 - LSZH H07RN-F ExtremeFlex90 Flexible Mains & Control Cable Belden Equivalent Cables Tri Rated Cables - BS6231 6491X H07V-R Cables - BS EN 50525-2-3 - PVC 6491B HO7Z-R Cables - BS EN 50525-3-41 - LSZH 6242 / 6243 Twin & Earth Cables - BS6004 - PVC 6242 / 6243 Twin & Earth Cables - BS7211- LSZH NYY-J Cables - IEC60502-1 - PVC SY Control Cables - BS50525-2-11 - PVC SY Control Cables - BS50525-2-11 - LSZH 318*Y Flex Cables - H05VV-F - PVC 6941AX/AB Single Core AWA Cables - PVC & LSZH 2491B / 6701B Cables - LSZH Steel Wire Armoured Cables - Aluminium - BS5467 - PVC Fire Alarm & Security Cables - BS5839/BS7629 Fire Alarm & Security Cables - Enhanced - BS5839 / BS7629 N2XH Cables - BS EN / IEC 60332-3-24 (c) - LSZH N2XH KEMA Approved Cables - LSZH EV-Ultra Electric Vehicle Power & CAT5e Cable ConnectEV Electric Vehicle Power & CAT5e Cable Bare Soft Drawn Copper Cables Bare Hard Drawn Copper Cables 6181Y Double Insulated ( Meter Tails ) Cables - BS6004 - PVC 6181B Double Insulated ( Meter Tails ) Cables - BS7211 & BS8573 / IEC60502 - LSZH 218*Y H03VV-F Flexible Cord 219*Y PVC Oval Flat Flexible Cables - BS6500 3093 / 3094 & 3095 PVC Heat Resistant Flexible Cables - BS EN 50265 318*B Flex Cables - HO5Z1Z1-F - LSZH Arctic Grade Flexible Cables - BS6004 - Table 44 Solar Cables - TUV Approved PV-Ultra Solar Cable 6491F Single Core Fireproof Cables Fireproof Mains & Control Cables - LSZH Fireproof Mains Cables - LSZH Fireproof Mains & Control Cables - Enhanced - LSZH Fireproof Mains Cables - Enhanced - LSZH 318* Tough Rubber Flex Cords H07ZZ-F Flex Mains & Control Cables - LSZH TQ Flexible Cables - EPR / CSP Type 4 Coil End Lead Cable 0361TQ Welding Cable - BS638 Part 4 YY Control Cables - BS50525-2-11 - PVC YY Control Cables - BS50525-2-11 - LSZH CY Control Cables - BS50525-2-11 - PVC CY Control Cables - BS50525-2-11 - LSZH BS8436 Protected Fixed Wiring Cable NYMJ Cables NHXMHJ Cables Security Alarm Cables UTP/FTP CAT5E/CAT6 Data Cables Internal Telephone Cables - BS4066 Coaxial Cables Bell Wire & Speaker Cables Defence Standard 61-12 Control Cables KNX Cables ENATS 09-6 Communications & Telephone Cables BS5308 Instrumentation Cables 6381Y DC Cables - PVC 6381B DC Cables - LSZH 6181X Mains & Cathodic Cables - BS7889/97 - PVC 6941X Armoured Cathodic Protection Cables - PVC Induction Loop Detector Cable - BS6500 / BS6195 DNO Concentric Cables - Split & Straight DNO Waveform Cable DNO 11KV Cable 11kV Armoured Mains Cable - Single Core - LSZH 11kV Armoured Mains Cable - 3 Core - PVC 11kV Armoured Mains Cable - 3 Core - LSZH 657*TQ Marine & Offshore Cables 658*TQ Marine & Offshore Cables XAI Marine Cables NEK606 BFOU Power & Instrumentation Marine Cable NEK606 RFOU Power & Instrumentation Marine Cable
Cable Accessories & Components Cable Management Industrial & Commercial LED Lighting Domestic LED Lighting Heating & Hand Dryers Site Equipment Switchgear & Control Switches & Sockets Ventilation Fans & Ducting Wiring Accessories & Consumables
01642 266013
0800 652 9229
Order and Helpline open now
Prices Ex. VAT Prices Inc. VAT
Free Delivery On orders over £50 to UK mainland
postcodes. Click to see exceptions.
Place Your Order before 2.30pm for same day dispatch Mon-Fri
Open 8.30am-5pm Mon-Fri, 8am-12pm Sat
Click & Collect Available from our Middlesbrough depot Cable Size Calculator Step by step size selector
 

Advanced MXP-509 Fault Tolerant Network Card MxPro 5

MXP-509
£439.95EX. VAT
£527.94INC. VAT
Low Stock
Order before 2.30pm for same day dispatch*
Order now to collect from our Middlesbrough Depot in 2 hours time*

Advanced Fault Tolerant Network Card for MxPro 5 – Your reliable Partner in Fire Alarm Networking

The Advanced MXP-509 Fault Tolerant Network Card is essential for seamlessly integrating MxPro 5 series fire alarm control panels, remote terminals, and network peripherals into a robust and scalable fire detection system. The Ad-NeT network system utilises standard fire-resistant two-core cable, offering distributed intelligence and cost-effective installation for small- and large-scale fire alarm networks.

Why Choose the MXP-509 Fault Tolerant Network Card?

  • Supports up to 200 control panels in a single network
  • Fault-tolerant peer-to-peer communication ensures uninterrupted data transfer
  • Maximum cable length of 1.5km per segment, with a total loop length of up to 20km
  • Instant network integration – Assign a node address to connect additional panels
  • Built-in network analyser for real-time diagnostics and monitoring
  • Windows-based PC-NeT Mx configuration software for advanced customisation
  • Fully monitored system that can withstand single cable faults without communication loss

Seamless Peer-to-Peer Fire Alarm Networking

The MXP-509 enables authentic peer-to-peer communication, allowing any input or output device to share critical data across the network. This ensures fire alarm signals and system information can be displayed and managed from any MxPro 5 control panel or remote terminal, providing complete situational awareness and instant system updates. The real-time monitoring capabilities of the MXP-509 Fault Tolerant Network Card ensure that any potential fire hazards are detected and addressed promptly, enhancing the overall fire safety of the system.

Effortless System Expansion & Integration-Your Fire Safety System, Your WayAdding a new control panel or terminal is quick and straightforward. By installing a network card and assigning a valid network node address, all other nodes in the Ad-NeT system immediately recognise the new panel, ensuring a seamless expansion process. The built-in network analyser provides real-time diagnostics and status updates, aiding in commissioning and troubleshooting.

Advanced Configuration & Zonal Control-Putting You in the Driver's Seat of Your Fire Safety SystemFor more complex fire alarm systems, the Windows-based PC-NeT Mx configuration software allows for sector-based programming, enabling:

  • Customised control keys for Mute, Silence, Resound, and Reset functions
  • Investigation delays, group disablement, and test instructions
  • Zonal-specific network information display
  • Cause-and-effect programming allows any input device to trigger any output device within the network

Standard Network vs Fault-Tolerant Network

Standard Ad-NeT+ Network:

  • Supports up to 32 network nodes (expandable to 50 with a signal buffer)
  • Maximum total cable length: 1.5km
  • Effective and reliable data transmission for small to medium-sized networks

Fault-Tolerant Network:

  • Supports up to 200 network nodes
  • Maximum cable length per segment: 1.5km
  • Total loop length: up to 20km
  • Fully monitored for short and open circuit faults
  • Capable of withstanding single cable faults without communication loss

Ideal Applications

The MXP-509 Fault Tolerant Network Card is ideal for use in:

  • Commercial buildings – Ensuring large office complexes have a unified fire detection system
  • Industrial facilities – Providing reliable, fault-tolerant fire alarm networking
  • Hospitals & Healthcare Centres – Enabling real-time monitoring across multiple zones
  • Educational institutions – Offering seamless fire alarm integration in large campuses
  • Multi-site complexes – Linking various buildings into a single fire alarm network.

 

The MXP-509 Fault Tolerant Network Card - Ordering

The Advanced MXP-509 Fault Tolerant Network Card is an industry-leading solution for scalable, fault-tolerant fire alarm networking. With easy installation, peer-to-peer communication, and advanced configuration capabilities, it is the perfect choice for small- and large-scale fire detection systems.